摘要:
采用高压管道粉尘在线检测装置对天然气站场内多管旋风分离器和过滤分离器进出口管道内颗粒物浓度和粒径分布进行测定,得到多管旋风分离器和过滤分离器的实际分离性能。现场测试结果与常压常温下过滤分离设备的性能测定结果对比表明:多管旋风分离器现场的分离效率与实验室测试结果相一致,常压常温工况下的性能测定数据可以作为评价高压实际工况运行的指标。过滤分离器现场测试结果与常压常温下测试结果存在差别,主要原因在于滤芯现场使用过程中,滤芯纤维失效会导致较大颗粒穿透,使过滤分离器效率下降。
关键词:  天然气管道  多管旋风分离器  过滤分离器  颗粒物在线检测
DOI:10.3969/j.issn.1673-5005.2013.05.021
分类号:TE 931.1 〖HTH〗
基金项目:国家“十二五”重大科技专项课题(2011ZX05017-005)
Performance measurement and analysis of filtration and separation equipment for natural gas transportation
JI Zhong-li
(College of Mechanical and Transportation Engineering in China University of Petroleum, Beijing 102249, China)
Abstract:
The concentration and size distribution of dust particles at the inlet and outlet of multi-cyclone separators and filters in two domestic natural gas stations are measured by the particle online measuring devices for high pressure gas, and the separation performances of in-site cyclones and filters are evaluated. These field test results are compared with the laboratory test results under atmospheric temperature and pressure. The field test results of multi-cyclone separators are in agreement with the laboratory test results, and so the data measured under atmospheric temperature and pressure can be used as the indicator for evaluating separation performance of multi-cyclone under high pressure condition. However, the field test results of filters show some differences from the laboratory test results. The overall efficiency of filters decreases with the operation period because some large particles can penetrate the filter candle.
Key words:  gas pipeline  multi-cyclone  filter  particle online measurement
版权所有 中国石油大学学报(自然科学版)编辑部 Copyright©2008 All Rights Reserved
主管单位:中华人民共和国教育部 主办单位:中国石油大学(华东)
地址: 青岛市黄岛区长江西路66号中国石油大学期刊社 邮编:266580 电话:0532-86983553 E-mail: journal@upc.edu.cn
本系统由:北京勤云科技发展有限公司设计