本文已被:浏览次 下载次 |
码上扫一扫! |
|
|
Flow and mass-transfer laws in a fiber film extractor |
FAN Yi-ping1,YOU Ming-yang1,E Cheng-lin1,LI Tao-zi2,LU Chun-xi1,GU Chun-lai2,SHI Ming-xian1
|
(1. State Key Laboratory of Heavy Oil Processing in China University of Petroleum,Beijing 102249,China ;2. New Baron Innovative Energy Technology Developinent INC, Beijing 100083, China )
|
Abstract: |
The performances of the fiber film extractor were investigated using a cold plexiglass pipe of 70 mm in diameter and 2630 mm in height. The influences of the operating and structural parameters on the flow and mass-transfer characteristics of the fiber film extractor were revealed. By analyzing the volume mass-transfer coefficient, the optimal operating flow-ratio and packed density were obtained. A flow model was built. Moreover, based on the theoretical analysis, Renault number was proposed as the design principle dimensionless number for fiber film extractor design purpose. The experimental results indicate that the optimal operating flow-ratio for a fiber film extractor is 5 while the best packed density is 2.8% ? |
Key words: fiber film extractor flow mass transfer packed density flow ratio Renault number design |
|
|